/CoolingSystem APC ACRC

CoolingSystem APC ACRC backgroundCoolingSystem APC ACRC
CoolingSystem APC ACRC backgroundCoolingSystem APC ACRC
Environmental Devices
UPSCoolingSystem APC ACRCDiesel Generator Deep SEACoolingSystem Tavan SarmaCoolingSystem Uniflair UG40/MP40CoolingSystem Uniflair BREF

CoolingSystem APC ACRC Monitoring

Apc.acrc.overview.en

Performance indicators and parameters of CoolingSystem APC ACRC monitored by Moein are:

Device General Info:

  1. Name
  2. Address
  3. Port Number
  4. Hostname
  5. Model
  6. Vendor
  7. Location
  8. Serial Number
  9. Firmware Version
  10. Hardware Revision
  11. Manufacturer Date
  12. Availability

Group Status:

  1. Group Coolant Output
  2. Group Coolant Demand
  3. Group Air Flow
  4. Group Maximum Rack Inlet Temperature
  5. Group Minimum Rack Inlet Temperature
  6. Active Flow Control System Status
  7. Group Cooling Set Point
  8. Supply Air Set Point
  9. Preferred Fan Speed Setting
  10. Fan Speed Control Setting
  11. Active Flow Control Bias Setting
  12. Group Number Of Cooling Units
  13. Group Configuration Type
  14. Percentage Of Glycol Mixture
  15. Gain Component Of The PID
  16. Integral Component Of The PID
  17. Derivative Component Of The PID
  18. Maximum Desired Fan Speed
  19. Number Of Active Flow Controllers
  20. Controller Lamp Test Status
  21. Altitude Of The Units Above Sea Level

Apc.acrc.details.en

Unit Status:

  1. Cooling Unit Operating Mode
  2. Unit Cooling Output
  3. Unit Cooling Demand
  4. Unit Air Flow
  5. Unit Rack Inlet Temperature
  6. Unit Supply Air Temperature
  7. Unit Return Air Temperature
  8. Unit Containment Differential Pressure
  9. Unit Air Filter Differential Pressure
  10. Unit Average Fan Speed
  11. Input Contact State
  12. Output Relay State
  13. Unit Power Source
  14. Fluid Valve Position
  15. Fluid Flow
  16. Entering Fluid Temperature
  17. Leaving Fluid Temperature
  18. Leak Sensor State
  19. Unit Air Filter Running Duration
  20. Unit Fan 1 Running Duration
  21. Unit Fan 2 Running Duration
  22. Unit Fan 3 Running Duration
  23. Unit Fan 4 Running Duration
  24. Unit Fan 5 Running Duration
  25. Unit Fan 6 Running Duration
  26. Unit Fan 7 Running Duration
  27. Unit Fan 8 Running Duration
  28. Unit Fan Left Power Supply Running Duration
  29. Unit Fan Right Power Supply Running Duration
  30. Unit Condensate Pump Running Duration
  31. DC Power Feed A Left Power Supply Running Duration
  32. DC Power Feed A Right Power Supply Running Duration
  33. DC Power Feed B Left Power Supply Running Duration
  34. DC Power Feed B Right Power Supply Running Duration

Unit Configuration Threshold and configs:

  1. Air Filter Service Interval
  2. Air Filter Service Interval Alarm
  3. Unit Rack Inlet Air High Temperature Threshold
  4. Unit Supply Air High Temperature Threshold
  5. Unit Return Air High Temperature Threshold
  6. Unit Incoming Fluid High Temperature Threshold
  7. Cooling Capacity Options Setting
  8. Startup Delay
  9. Idle On Leak Detection
  10. Configured Power Source Of The Unit
  11. Normal State Of The Input Contact
  12. Normal State Of The Output Relay
  13. Source Of Output Relay Change
  14. Idle On Cool Failure

Apc.acrc.kpi.en